The standard variable area flow meter is composed of a measuring tube and a on-site indicator. On-site indicator can be optional to install an additional electric component, which is suitable to measure liquid and gas.
This variable area flow meter adopts the variable-area measuring principle and the measuring component is composed of a conical measuring tube and a floater. The floater can move up and down freely in the conical measuring tube, to change the flow area in the tube. The vertical position of the floater in the conical measuring tube will change with the change of flow, the floater position will be transmitted to the indicator dial via magnetic transmission system, and it can indicate the flow value on site, and also output signal to realize remote display and control.
This variable area flow meter can be widely used in the flow measuring process of complicated and severe environmental conditions such as petroleum, chemical engineering, power generation, pharmaceuticals, food and water treatment industries, as well as various medium conditions.
Specifications
Measuring range |
Water (20ºC)   6~150000L/h Air (101.3kPa 20ºC) 0.05~4000m3/h |
Measuring range ratio | 10:1 (20:1 for special type) |
Accuracy |
1.5 grade 1.0 grade |
Working Pressure |
DN15~DN50Â Â PN4.0MPa (25MPa for special type) DN80~DN100Â Â Â Â PN1.6MPa (16MPa for special type) |
Jacket pressure rating | 1.6MPa |
Media Temperature |
Sandard Type: -80ºC~+220ºC Hgh temperature type: 400ºC Lning PTFE type: ≤85ºC |
Ambient Temperature |
Pinter type: -40ºC~+120ºC Eectric remote transmission type: -30~+65ºC, |
Media Viscosity |
DN15: ≤5mPa.s (H15.1~H15.3): ≤30mPa.s (H15.4~H15.9) DN25: ≤250mPa.s DN50~DN150: ≤300mPa.s |
Liquid crystal display (LCD) |
Idication range for instantaneous flow rate: 0~50000. Idication range for accumulative flow rate: 0~99999999. |
Output |
Sandard signal: two-wire 4~20mA Pulse signal: minimum interval is 50ms  |
Alarm output |
Instantaneous flow rate alarm for upper limit or lower limit.   Sandard type: open-collector output (MAX100mA, 30VDC Inner impedance 100Ω. Secial type: relay output (The maximum contact capacity is 5A AC250V) |
Power supply |
Sandard type: DC24V (DC10.8V~DC36V)Â AC type: AC220V (AC85V~AC265V) |
Connection type | Sandard type: DIN2501 flange    |
Electrical Interface | M20×1.5, PG11,1/2″NPT15 |
Protection Grade |
IP6516, explosion-proof sign: Intrinsic safety type: ExiaIICT3~6Â Â Â Â |
Batch Type Oil Distillation Plant
The Waste Engine Oil Distillation Plant is used to refine waste engine oil, crude oil and fuel oil after pyrolysis process into diesel grade oil, gasoline or and base oil. The daily capacity of this plant is about 5-6 tons.
Flow-chat of waste engine oi Distillation Plant
Advantage of waste engine oi distillation plant
1. Unique and original manufacturing and technology with our own formula of our equipments in China;
2. Unique horizontal design, high oil output with about 90% oil yield and 100% conversion rate, highly effective and profitable;
3. Good quality end product oil as the substitution of standard diesel oil in usage;
Automatic submerged welding technology, ultrasonic nondestructive testing, both manual and the automatic safety devices;
4. Sync gas recycling system: fully burned after recycling and utilization, saving fuel and preventing pollution;
5. National patent, unique heat insulation shell: high efficiency temperature keeping, excellent energy-saving effect;
6. High condensing efficiency condensers with more oil output. Good quality oil, longer lifetime, and easy to clean;
7. National patent water film smoke scrubbers: efficient removal of the acid gas and dust of the smoke, environmental friendly to meet related national standards.
Technical Parameter of Waste engine Oil Distillation Plant
NO. |
Item |
Technical Parameter |
1 |
Suitable Raw Materials |
Waste engine oil, Pyrolysis fuel oil, crude oil |
2 |
Structure |
Horizontal Type |
3 |
Capacity(24 hours) |
3.5-6.5Mt |
4 |
Work Pressure |
Normal Pressure |
5 |
Oil Yield |
80%-90% |
6 |
Power |
18 kw/H |
7 |
Cooling Method |
Cycle water |
8 |
Condensers |
4 pieces of Vertical condensers |
9 |
Emission Treatment |
New DE-sulfurization Smoke Scrubbers |
10 |
Heating Method |
Hot Air |
11 |
Type of Installation |
With Foundation |
12 |
Noise dB(A) |
≤85 |
13 |
Dimension of Reactor(mm) |
Ф2200×6000 Ф2500×8800 |
14 |
Operating Mode |
Semi-continuous Operation |
15 |
Main Chamber Weight (MT) |
10~13Mt |
16 |
Total Weight(MT) |
25~35Mt |
17 |
Installation Space Required |
35m*15m |
18 |
End Product |
Non-standard diesel oil |
19 |
Manpower |
1~2/shift |
20 |
Shipment Requirement |
2*40HC=Ф2200×6000 1*40HC+1*40FR=Ф2500×8800 |
Batch Type Oil Distillation Plant
Batch Type Oil Distillation Plant,Batch Distillation Column,Waste Oil To Diesel,Oil Distillation Plant
Shangqiu Jinpeng Industrial Co., Ltd. , https://www.recyclings.nl