What should be noted when the magnetic separator is turned on and off?

What should be noted when opening and stopping the magnetic separator and operating it?

(1) Before driving, pay attention to check the power line, transmission, lubrication system and equipment around the situation, confirm the normal, can drive after the obstacles;

(2) The driving of the equipment shall be carried out in a certain order. Generally speaking, driving is carried out from the back to the front according to the process, and parking is reversed;

(3) When driving, first open the water pipes of each part of the equipment, the discharge port should start smaller, then feed the mine, and gradually adjust to normal operation;

(4) When all equipment is parked, contact the pump management personnel first, then stop the mine, and gradually close the water gate and the discharge port. If the water gate is closed without contact, the pump may collapse. Local parking should also be contacted in advance to determine the number of pump starts.

The operation of the magnetic separation process is to minimize the tailings grade under the premise of ensuring the quality of the concentrate. To this end, the operator must be "two diligence" and "two quasi". "Second Qin" is a diligent inspection and diligent contact. Diligent inspection is in the production process, the nature of the original ore, the concentration of the grinding, the color of the pulp, the quality of the product, and the condition of the water and equipment are normal, so that you can find out the problem in a timely manner. Always contact each other between the upper and lower processes, communicate the situation, and be proud of mastering the overall process of the festival. "Second standard" is an accurate judgment, and the heap is adjusted. That is to say, on the basis of “two Qin”, accurately determine the changes in ore properties and other process factors, and timely and accurately adjust the process.

AMRTA series air cooled water chillers and heat pumps are designed for outdoor installation and generally for both commercial and industrial application with the ability of 24 hours/day operation. The units are factory tested and on site installation will be completed only by connecting with the water kit components and power supply. 


Characteristics:

1.With world famous brand componets. Such as COPELAND/DANFOSS brand scroll compressor. BITZER brand screw compressor. SCHNEIDER brand electric parts. EMERSON brand refrigrant valves.

2.With environment friendly refrigerant R407c/R410a and R134a.

3.Protection function complete unit with overload, short circuit protection, frost protection, high and low voltage protection, overheating protection and other functions.

Air Cooled Water Chiller series:

1. Air cooled water Mini Chiller. Cooling capacity 20kW/25kW/30kW/35kW/40kW/50kW. With scroll compressor.

2. Air cooled water moular chiller. Cooling capacity 60kW/100kW/130kW/200kW/260kW. With scroll compressor

3. Air cooled water screw chiller. Cooling capacity 150kW/180kW/250kW/320kW/380kW/430kW/500kW/570kW / 640kW/ 700kW/760kW/870kW/930kW/1000kW/1180kW. With screw compressor


Air Cooled Mini ChillerModular Air Cooled ChillerScrew Air Cooled Chiller

Air Cooled Water Chiller

Air Cooled Water Chiller,Packaged Air Cooled Water Chiller,Water Chiller Air Conditioner,Modular Air Cooled Water Chiller

Jinan Amrta Air Conditioning Co.,Ltd , https://www.waterchiller.pl